Airfoils.Pro
database / Gottingen / GOE 396 AIRFOIL
CAMBEREDGOTTINGENSELIG-DATABASETHIN

GOE 396 AIRFOIL

Cambered · 5% thick · low-to-mid Re
Compare↓ Download
PROFILEGOE 396 AIRFOIL
surfacecamber line
GEOMETRY · AREA METRICS
max thickness4.7% @ 22%c
max camber5.8% @ 40%c
LE radius0.24%c
area upper / chord0.0538
area lower / chord0.0189
area camber / chord0.0363
TE thickness0.00%c
DOWNLOAD COORDINATES

Polars

Preliminary
NeuralFoil
-0.1412-50.45443.3331.0511.671.64520ClAngle of attack (°)
Why this curve

This is a NeuralFoil prediction from the stored profile coordinates and the selected flow condition, with AeroSandbox compressibility corrections. It is not a completed OpenFOAM calculation.

Prediction error has not been calibrated for this condition. No accuracy interval is claimed.

The compressibility correction is a low-fidelity estimate, not a resolved shock or compressible CFD solution.

Geometry fit: RMS error 0.05292% of chord; maximum error 0.2355%.

NeuralFoil 0.3.3 · AeroSandbox 4.2.10

Curve summary

NeuralFoil · Within -5° to 20°

Maximum lift / drag
165.3
Angle at maximum lift / drag (°)
6
Minimum Cd
0.005965
Maximum Cl
1.497
Angle at maximum Cl (°)
8
Cd at zero lift
—
Cm at zero angle
-0.1262
CFD points
SOLVER WORK0 conditions · 0 engine jobs